Examples of common issues we see in older homes

See if you have any of these conditions and contact
us to see how we can help you

As you review these photos, Please note that Temporary Steel Support Lally Columns are not allowed per Massachusetts
Building Code

Rusted Temporary Lally Column next to Deteriorated Existing Lally Column

Split Lally Column

 

Temporary Lally Column Next To Deteriorated Column

 

Temporary Column on Unstable Footing

 

Temporary Column on Unstable Footing

 

20221026_104427_edited.jpg

Deteriorated Lally Columns

 

Unsafe Shimming and Blocking of Timber Beam

 

Temporary Lally Column used as a Permanent Column
 

Split Timber Beam

 

Split Joist

 

The Lally Lock Column System consists of the following:

1.   3.5 inch concrete encased   
   steel column

2.  Top Plate:  Steel plate with 
     Restraint screw

3.  Bottom Plate
    Option of 2 Styles:

    A. Bottom Plate with    
        restraint screw

    B.  3 inch Adjustable base
 

lally.jpg

Here are the products we use to replace your existing deteriorated lally column and/or temporary steel lally columns.

Lally-Lock-Cap 1.png

Top Plate:  Steel plate with Restraint screw
 

Lally-Lock-Base-Plate.png

Bottom Plate: 
Option A Steel Plate with restraint screw

   

Adjustable-Column.png

Bottom Plate:
Option B Steel Plate with
.3 inch Adjustable base
 